Specially designed to meet your requirements of manipulation precision, stability and linearity.

DTP100 Micropositioner

Application:              I-V/C-V Probing.


Features:

Cost-effective          Very cost-effective micropositioner.

Compact                    Small footprint fits your space tight application.

Stable                         Spring loaded X-Y-Z, stable and backlash free.

Linear motion           Precisely grinded finish glides assures motion linearity.

Ease of use                Available in right and or left hand manipulation.

Techical Specs

DCP100 Micropositioner

Application:                 I-V/C-V, RF Probing.


Features:

VF XY adjusters           Vibration free XY adjusters. 

                                         Designed to isolate manipulation vibration, ease of tip to pad alignment.

Stable and flexible      Spring loaded X-Y-Z, stable and backlash free.

                                         5kg.f magnetic mounting with ON/OFF function, stable when turned on magnet.

                                         Flexble to move when turned off magnet.

Precise Movement      100TPI high precision screw and bushing set to assure accurate movement.

                                         Originated from U.S.

Linear motion               Precisely grinded finish glides assures motion linearity.

Ease of use                    Available in right and or left hand manipulation.

Techical Specs

HPP100 Micropositioner

Application:              Ultra Stable I-V/C-V Probing.


Features:

VF XYZ adjusters      Vibration free XYZ adjusters.

                                      Designed to isolate manipulation vibration, ease of tip to pad alignment.

Stable and flexible  Spring loaded X-Y-Z, stable and backlash free.

                                      5kg.f magnetic mounting with ON/OFF function, stable when turned on magnet.

                                      Flexble to move when turned off magnet.

Precise Movement   100, 200 and 300TPI high precision screw and bushing sets available, assure accurate 

                                       X-Y-Z movement. Originated from U.S.

Linear motion            Precisely grinded finish glides assures motion linearity.

Ease of use                 Available in right and or left hand manipulation.

Techical Specs

RFP100 Micropositioner

 Application:              High-performance RF, multi-contact/mixed signal probing.

                                      High-performance versatile wafer level reliability probing.

                                      Single-ended broadband/mmWave, THz, source/load pull, RF noise probing.

Features:

Stable and rigid         Designed with larger XYZ glides and low profile, stable and rigid for RF and mmW 

                                       probing. 

Vibration free             Vibration free XY adjusters. Very protective to expensive and fragile RF/mmW probe 

                                       tips.

                                       Designed to isolate manipulation vibration, ease of tip to pad alignment.

Backlash free              Spring loaded X-Y-Z, stable and backlash free.

Linear motion             Precisely grinded finish glides assures motion linearity.

Mounting Options     Magnetic mounting or bolt down mounting availalble.

Techical Specs

RFP100-mmW Micropositioner

Application:              Specially deigned to mount frequency extenders or tuners.

                                     High-performance RF, multi-contact/mixed signal probing.

                                     High-performance versatile wafer level reliability probing.

                                     Single-ended broadband/mmWave, THz, source/load pull, RF noise probing.

Features:

Stable and rigid       Designed with larger XYZ glides and low profile, stable and rigid for RF and mmW 

                                     probing. 

Vibration free           Vibration free XY adjusters. Very protective to expensive and fragile RF/mmW probe 

                                     tips.

                                     Designed to isolate manipulation vibration, ease of tip to pad alignment.

Backlash free            Spring loaded X-Y-Z, stable and backlash free.

Linear motion           Precisely grinded finish glides assures motion linearity.

Techical Specs