FemtoProbe


Application:                   Ultra low noise I-V measurement 

Current Leakage:        <10fA

Cable:                                 N.A. Puchased Separately. CA-SMA-TRIAX-MTM or  CA-SMA-BNC-MTM

Connector:                      SMA, female, gold plated

Breakdown Voltage: 500V

Adapter:                           Adapters to positioner are  purchased separately. FP-A100 or FP-A200.

probe holder low noise probe DC RF probe high current probe high voltage probe probe arm adpater

CPA-10 Probe


Application:                    Excellent performance with LCR, Low noise I-V measurement 

Current Leakage:        <10fA

Cable:                                 N.A. Used with CA-SSMC-TRIAX-FTM or  CA-SSMC-BNC-FTM

Connector:                      SSMC, female, gold plated

Breakdown Voltage: 500V

Adapter:                            Adapters to positioner are  purchased separately. FP-A100 or FP-A200.

COAX probe holder low noise probe  high current probe high voltage probe probe arm adpater

S10-COAX-BNC   Probe Holder


Application:                    Optimized I-V measurement

Current Leakage:        <10pA

Cable:                                 2m coax cable (or customized lengths)

Connector:                      BNC, male, silver(contact finish)

Breakdown Voltage: 500V

Adapter:                            6mm diameter bended solid structure.

image8

S10-COAX-BNC   Probe Holder


Application:                    Optimized I-V measurement, basic C-V measurement, LCR measurement.

Current Leakage:        <10pA

Cable:                                 2m coax cable, X2 (or customized lengths)

Connector:                      Dual BNC, male, silver(contact finish)

Breakdown Voltage: 500V

Adapter:                            6mm diameter bended solid structure.

COAX probe holder low noise probe pulsed I-V DC RF probe probe arm adpater

S10-COAX-SMA   Probe Holder


Application:                     Ultra-fast I-V tests: pulsed I-V, transient I-V, and pulsed sourcing.  

Current Leakage:        <10pA

Cable:                                 2m coax cable (or customized lengths)

Connector:                      SMA, male/female, gold plated

Breakdown Voltage: 500V

Adapter:                            6mm diameter bended solid structure.

TRIAX probe holder low noise probe pulsed I-V DC RF probe probe arm adpater

S10-TRIAX   Probe Holder


Application:                    Low noise I-V measurement 

Current Leakage:        <100fA

Cable:                                 2m triax cable (or customized lengths)

Connector:                      Triax connector, male, gold (contact finish)

Breakdown Voltage: 500V

Adapter:                            6mm diameter bended solid structure( probe arm ).


* Female connector available upon request.


COAX probe holder low noise probe pulsed I-V DC RF probe probe arm adpater

S10-BA   Probe Holder


Application:                    Basic I-V measurement 

Current Leakage:        <10nA

Cable:                                 2m flexible cable (or customized lengths)

Connector:                      Banana plug , shrouded, nickel (contact finish)

Breakdown Voltage: 500V

Adapter:                            6mm diameter bended solid structure.

COAX probe holder low noise probe pulsed I-V DC RF probe probe arm adpater

FP-A100  Probe to Positioner Adapter


Application:                              FemtoProbe and CPA-10 probe adapter to positioners. 

Positioner Compatibility:DTP100, DCP100 

Features:                                     Cost-effective rigid stailess structures.

COAX probe holder low noise probe pulsed I-V DC RF probe probe arm adpater

FP-A200  Probe to Positioner Adapter


Application:                             FemtoProbe and CPA-10 probe adapter to positioners. 

Positioner Compatibility:DTP100, DCP100 

Features:                                     Adjustable in X-Y-Z directions, improves set up efficiency. 

coax probe

FemtoProbe Replacement Probe Tips


Application:      Low noise I-V measurement, FemtoProbe replacement tips. 

Tip Diameter:  1, 5, 10, 20 micron 

Bends:                   45/60 degree with one bend or dual bends. 

tungsten probe tips

Solid Tungsten Probes (Disposable)


Application:      I-V/C-V measurement, failure analysis 

Tip Diameter:  5, 10, 20 micron 

Length:                 50mm

Coating:               Nikel

tungsten probe tips

Catwhisker Tungsten Probes (Disposable)


Application:     I-V/C-V measurement, failure analysis 

Tip Diameter:  0.2, 1, 3micron 

Length:                50mm

Coating:              Nikel(shaft)

RF probe mmW probe Multicontact wedges

RF/mmW, Multicontact Probe Wedges


Application: High-performance RF, multi-contact/mixed signal probing, Single-ended 

                             broadband/mmWave, THz, source/load pull, RF noise probing 

Footprint:      SG, SG, GSG, or differential

Pictch:             Customized

CS:                      N.A.

Adapters:       N.A.


Calibration substrate and adapters are purchased separately.

RF probe adapter Probe arm

RF100 RF/mmW Probe  to Positioner Adapter


Application:      Adapter for RF probes, multicontact wedges to positioners  

Compatibility: DCP100, RFP100 

Features:            Rigid structures. 10° horizontal tilting range for probe tip planarity alignment 

                                  to pads.Available in south, east, north and west version. 

Model 12C probe Picoprobes GGB

High Impedance Active Probe


Application:                 High speed, high input impedance active probe for measuring the 

                                             internal node voltage of integrated circuits.  

Input Capacitance : 0.1pF

Input Resistance :    1.0 megohm

Rise/Fall Time:           0.8ns

Bandwidth:                   DC~500MHz

Linearity:                        0.5%

Voltage Range:            -10~20V

Gain Accuracy:             +/-3%

Signal Attenuation:    High input impedance oscilloscope 10 to 1